Working in Trans World Associates (Pvt) Ltd as Manager O&M at Submarine Optical Fiber Cable Landing Station & Data Center since 10-Aug-2015.
Looking after all other collocation of Karachi.
Machines/Equipment installed at (CLS) Cable Landing Station and other collocations.
1- Generators
2- Rectifiers
3- UPS
4- Chillers
5- Air-conditioning Units
6- Precision Cooling Units
7- Motor & Pumps
8- Cooling Towers
9- Fire Protection System
10- Monitoring Systems
Responsibilities:
1- Leading O&M teams at all locations in Karachi.
2- Managing all machines and equipment related to power and HVAC.
3- Managing the load and timely upgrading of the power setup as per load/requirements.
4- Preparing BoQs/RFQs for new installations, upgrades, and new projects; analyzing proposals to ensure they align with the BoQ and are appropriate for the requirements.
5- Ensuring site/equipment readiness for the installation of telecom equipment.
6- Preparing reports and managing all data/records.
7- Preparing the budget.
8- Coordinating with vendors and procurement.
9- Coordinating with other departments.
10- Visiting all locations periodically to ensure the physical condition of related areas and equipment.
11- Providing required data, fuel consumption records, and any other records as needed to management, finance, auditors, etc.
Worked in Indus Motor Company (Toyota) as an Electrical Assistant Team Leader in Co-Generation Power plant from 12-Apr-2011 to 09-Aug-2015.
Responsibilities:
1- Corrective and preventive maintenance and troubleshooting of MCC Panels (Power & Control) for Generators, Turbines, Boilers, Hot Water Generators, and Chillers; maintenance of all electrical equipment installed in the Co-Generation Power Plant.
2- Monitoring and maintenance of Power Transformers (11 KV/400V) and 11 KV Vacuum Circuit Breakers.
3- Maintenance and troubleshooting of Low Voltage Panels, PF Improvement Panels, and Motors.
4- Thermography of Electrical Panels, DBs, and Motors.
5- Testing of Earth Pits/Grounding.
6- Insulation Testing of Transformers, High Voltage, and Low Voltage Cables.
7- Operating Gas Generators, Diesel Generators, and Gas Turbines in the absence of operational staff.
8- Operation of Chillers and Hot Water Generators in the absence of operational staff.
@ Worked in K-Electric as a Grid Operating Officer in System Operation from 24-Oct-2010 to 10-Apr-2011.
Responsibilities:
1- Monitoring of all equipment installed in the Grid Station, including 250 MVA (220KV/132KV) Transformer, 30 & 40 MVA (132KV/11KV) Transformers, 11KV, 132KV & 220KV Breakers & Transmission Lines, Protection System, Rectifiers, Battery Banks, etc.
2- Operation of EHT 220 KV and 132 KV Transmission Lines.
3- Operation of HT 11 KV Distribution Feeders.
4- Operation of Auto and Power Transformers.
5- Reporting to the related department in case of any abnormality or emergency.
6- Responsible for maintaining records of all operations, faults, and activities.
Worked in K-Electric as a Grid Operating Officer in System Operation from 24-Oct-2010 to 10-Apr-2011.
Responsibilities:
1- Monitoring of all equipment installed in the Grid Station, including 250 MVA (220KV/132KV) Transformer, 30 & 40 MVA (132KV/11KV) Transformers, 11KV, 132KV & 220KV Breakers & Transmission Lines, Protection System, Rectifiers, Battery Banks, etc.
2- Operation of EHT 220 KV and 132 KV Transmission Lines.
3- Operation of HT 11 KV Distribution Feeders.
4- Operation of Auto and Power Transformers.
5- Reporting to the related department in case of any abnormality or emergency.
6- Responsible for maintaining records of all operations, faults, and activities.
• Operation, maintenance & trouble shooting of Diesel generators, different type of air conditioning units Rectifiers, UPSs & Fire Protection System.
• Delivered uninterrupted electrical supply and to keep maintain required temperature in MSC and equipment rooms.
• Efficiently performed all necessary engineering calculations, specifications and drawings associated with sizing and specifying of engineered HVAC.
• Installation of DBs & breaker in panels along with cabling as well as new split type air-conditioning units.
• Organized Preventive maintenance of Diesel Generator also repairing & maintenance of air-conditioning units.
• Immediate action & Trouble Shooting in case of any interruption/abnormality.
• Maintenance of ATS panels and other Electrical panels and DB.
Worked in Mobilink (Jazz) as a Senior Electrical & HVAC Technician in O&M department at MSC (Micro Switch Centre) from 01-Jan-2008 to 19-Oct-2010.
Responsibilities:
1- Operation, maintenance & trouble shooting of Diesel generators, different type of air conditioning units Rectifiers, UPSs & Fire Protection System.
2- Installation of new split type air-conditioning units.
3- Responsible to provide uninterrupted Electrical supply & to keep maintain required temperature in MSC and Equipment Rooms.
4- Immediate action & Trouble Shooting in case of any interruption/abnormality.
5- Repairing & Maintenance of Air-Conditioning units.
6- Preventive maintenance of Diesel Generator.
7- Maintenance of ATS panels and other Electrical panels and DB.
8- Installation of DBs & Breaker in panels along with Cabling